 Address / SCSI
 Hartmann Pushwheels
  Electrical Data
Operating voltage Max. 40V  
Contact load, static Max. 0,5A  
Contact load, dynamic (resistive) Max. 100mA  
Contact resistance type AK (measured from the supply line to the output) < 120mOhm  
ESD protection Max. 8 kV
  Material
Housing PPO  
PC board base material FR 4 or CEM 3 DIN IEC 249-2  
Contact surface Au over Ni on Cu  
Sliding contact Au over Ni on CuSn6
  Technical Data
Permissable ambient temperature –20...+80°C  
Expected life (switching cycles) > 104  
Actuating force approx. 5 N  
Weight approx. 2 g  
Digit heigth (10-digit) 3,1/ 2 mm  
Click action marked
  Codes
Codes switching positions printing  
111 decimal 10 0-9  
301 hexadecimal 16 0-15 (0-9-A-F)
  Standard Colors
Type 2  
housing drum printing  
black black white
  Special Features on Request
•Stopping 0-7  
•Cable Harnessing  
•Special printing  
  Pin Connections
 
The switching mode is shorting, i.e. even during actuation at least one output is connected to input C.
  Dimensions
  Print Versions
 
pc board short, order description AK  
 
comb-type pcb, order description AKK
  Connections with Header
 
 
   
  Click here to ask us a question NEW: Download a PDF of All Panel Meters:
  All Panel Meters PDF
(compressed zip file, 4.1 MB;)

 
This PDF does not include sensors or switches


 


Distributors welcome.