The DPL-8 provides a loop powered 0.98", 3 1/2 digit LCD (standard black numerals) with optional 24Vdc powered red, blue, amber, or green negative backlight. It is compatible with virtually any 4 to 20mA dc process loop. User selectable °F, °C, PSI, and % engineering units can be displayed. Fully loop compatible. Separate zero and span adjustments. Decimal point user selectable. Factory calibration available.




| Display: |
Digits: |
3 œ Digits (±1999 counts)
|
|
|
Type: |
0.98? ( 24.9 mm)
|
| Backlighting*: |
Optional Red Negative (red numbers/black background)
|
| |
Optional Blue Negative (blue numbers/black background)
|
| |
Optional Green Negative (green numbers/black background)
|
| |
Optional Amber Negative (amber numbers/black background)
|
| Polarity: |
Automatic, ?-? Displayed.
|
| Decimal Points: |
3 Position, User Selectable
|
| Overload: |
Three lower order digits blank for inputs >1999 & <-1999
|
|
|
Hold: |
Display Hold Function is Standard
|
|
|
Annunciators: |
PSI,°F,°C,% (user selected),
|
|
Inputs: |
Ranges: |
±200.0mV, +/-2.000V, +/-20.00V DC, 4-20mA
|
|
|
Configuration: |
Bipolar, Differential
|
|
|
Protection: |
±350V DC, (±100V DC on 200mV Range)
|
|
|
|
(±30 mA on 4-20mA)
|
|
|
Impedance: |
>1 MW, (>10 MW on 200mV Range) |
|
Performance: |
Accuracy: |
±(0.05% FS +1 counts)
|
|
|
Conversion Rate: |
3 per Second
|
|
|
Normal Mode Rejection: |
>30 db @ 60 Hz
|
|
|
Common Mode Range: |
±1V DC
|
|
|
Common Mode Rej.: |
>86 dB
|
|
|
Zero Adjustment: |
Automatic
|
|
|
Warmup: |
10 Minutes Typical
|
|
|
Temperature Coeff.: |
±100 ppm per °C Typical
|
|
Environment: |
Operating Range: |
-10 to 50 °C
|
|
|
Storage Range: |
-40 to 75 °C
|
|
Power Supply: |
Powered by mA control loop. Loop Burden 300 W nominal
|
|
|
Optional Backlight: |
24V DC at 35 mA typical
|
|
Mounting: |
Snap-In Panel Mount
|
|
Connection: |
4 screw terminal (4-20mA)
|
|
|
13 pin male connection (voltage)
|
|
|
13 pin connector/wiring harness included |
Provides a large,.98?, 3-1/2 digit display.
• Optional Red, Blue, Green or Amber backlighting
• Decimal point user selectable
• Eng. units user selectable
• Snap-in panel mounting
• Gasket and clamp provided for NEMA 4 or 12 applications