1 TRIMMER FOR THE SENSING RANGE ADJUSTMENT: The photocell is supplied with max. sensing range with the trimmer totally rotated in the clockwise direction. The sensitivity reduces by rotating the trimmer in the anti-clockwise direction.
|
|
2 SWITCH NPN/PNP: The photocell is supplied with the switch in P (PNP output). To change to NPN turn the switch to N in the anti-clockwise direction. WARNING! For a correct working of the unit, do not carry out the switching when the photocell is powered.
|
|
3 GREEN LED - STABILITY INDICATOR: This led is on when the level of the output signal and the alignment of the photoelectric sensors are in the optimum position. In the case that the led is off this indicates that the lens is obscured or for the types with direct reflection a possible alteration of the dimension or color of the object to be detected.
|
|
4 YELLOW LED - OPERATION INDICATOR: This led is on when the object to be detected enters the sensing range of the photocell giving output signals.
|
|
N.B. SENSITIVITY ADJUSTMENT
|
|
• After adjustment the sensitivity can vary depending on variations in the object or conditions in the area of installation.
|
|
• As reflection varies in relation to the object, adjustment should be carried out with the object present.
|
|
• After having carried out adjustment, the fixing of the way and the curvature of the fiber should not be changed.
|
|
PROCEDURE FOR THE DIRECT REFLECTION FIBER OPTICS ADJUSTMENT: |
PROCEDURE FOR THE THRU-BEAM FIBER OPTICS ADJUSTMENT:
|
|
Adjust the sensitivity to minimum turning the trimmer anticlockwise. Position the object to be sensed at the required distance in relation to the end of the fiber and turn the trimmer slowly clockwise until the yellow led lights up. Continue turning the trimmer until the green led lights up. Recheck that the calibration is correct by using the object and possibly by repeating the procedure. |
Adjust the sensitivity to minimum turning the trimmer anticlockwise. Position the end of the fibers at the required distance and turn the trimmer slowly clockwise until the yellow led lights up. Continue turning the trimmer until the green led lights up. Re-check that the calibration is correct by using the object and possibly by repeating the procedure.
|
|
IMPORTANT: in the presence of objects to be sensed the yellow led should be illuminated. |
IMPORTANT: in the presence of objects to be sensed the yellow led should be illuminated.
|
|
Output functions in the absence of the objects to be sensed. |
Output functions in the absence of the objects to be sensed.
|
|
NO output = black wire (H version = PIN 4) |
NC output = black wire (H version = PIN 4)
|
|
NC output = white wire (H version = PIN 2) |
NO output = white wire (H version = PIN 2) |