View Cart | Contact Us | My Account 
Call us Toll-Free: 888-472-6676 
 Resistance Temperature Device
 Simplify circuit design; Resistance temperature device (RTD) measurements.
The DPV-3 can be used to significantly reduce the complexity of external circuits required to handle many sensors.

For example RTDs usually require complex circuits to eliminate the offset created by the nominal resistance of the RTD sensor. In the circuit below, all that is required is a 1mA current source, an amplifier set for a gain of 70 , a 100 ohm Pt RTD, and a DPV-3.
0 °C output = 100 ohms X 1 mA X 70 = 7.00 volts
100 °C output = 138.5 ohms X 1 mA X 70 = 9.66 volts
None of the parameters are critical and need not be held to tight tolerances. There are no separate adjustments required in the external circuit. Both offset and span are done by the DPV-3

The RTD sensor can placed in a stirred ice batch (0 °C) and the DPV-3 adjusted to display 00.0 °C. Next the RTD sensor is placed in boiling water (100 °C) and the DPV-3 is adjusted to display 100.0 °C.

This even eliminates RTD sensor interchangeability. In addition the °C annunciator on the DPV-3 can be enabled.
Related products:
 

DPV-4 Series - Voltage Powered, 4 1/2 digit LCD Digital Panel Meters Adjustable Voltage Input  

DPV-809 Series - LARGE LCD Rangeable Voltage Digital Panel Meters - 3 1/2 digit  

Other Voltage/Loop Meters
 
 
   
  Click here to ask us a question NEW: Download a PDF of All Panel Meters:
  All Panel Meters PDF
(compressed zip file, 4.1 MB;)

 
This PDF does not include sensors or switches


 


Distributors welcome.
Panel Meters | Count / Time Meters | Sensors
HVAC Controls | Switches | View All Categories
Home | PDF Center |
Contact Us
Acculex / HR Components
PO Box 10300 - Bedford NH 03110
888-472-6676 phone - 888-210-0119 fax  
 (International:  1-603-472-4727 phone -  1-603-472-2159 fax)