SC40 Specifications
INSTRUCTIONS FOR CORRECT INSTALLATION ![]() SC40P-AE35 DELAYED - AVAILABLE RANGE SC40P-AE35 TE NO, delay on energization N.O. contact.
In the absence of material the sensor has an open contact. When the material enters the sensing area, the delay set starts. A the end of this time the contact closes. When the material leaves the sensing area, the contact opens instantaneously. SC40P-AE35 TE NC, delay on energization N.C. contact. In the absence of material the contact of the sensor is closed. When material enters the sensing area, the contact opens. When material leaves the area, the delay set starts, after which the contact closes. SC40P-AE35 TD NO, delay on de-energization N.O. contact. In the absence of material the contact of the sensor is open. When material enters the sensing area, the contact closes. When material leaves the area, the delay set starts, after which the contact opens. SC40P-AE35 TD NC, delay on de-energization N.C. contact. In the absence of material the contact of the sensor is closed. When material enters the sensing area, the delay set starts, after which the contact opens. When material leaves the area, the contact closes instantaneously. RANGE OF STANDARD TIME DELAY FROM 1 to 15 minutes. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||